Skip to content
Fire Safety Audit
Objective OF Fire Safety Audit:
To carry out a systematic, critical appraisal of all potential Fire hazards involving personnel, premises, services & operation method
To ensure that occupational Safety & Health System fully satisfy the legal requirements and those of company’s written safety policies , objectives & progress
Scope of Work
Fire Hazard Identification
-
Identifying potential fire / explosion hazards / risks in the Premises and suggesting appropriate preventive measures.
-
Evaluate the Fire risk in each operation / area.
Fire fighting system
-
Evaluate the location of the Fire pump house and water storage tank to meet the Statute and standard requirements and the availability of nearby hazards.
-
Adequacy of the underground and above ground fire water tank and pumping capacit.
-
Overhead tank and its interconnection with Fire water network, and backup supply.
-
Configuration of the pumps and valves for the hydrant and sprinkler system.
-
Checking the Adequacy of the sprinkler system, detection system, operating temperature / other parameter
-
Fire detection and alarm system
-
Adequacy of the Fire detection and alarm (FDA) system with respect to relevant standards, positioning of the detectors with respect to ventilation system, beam depth, obstructions, etc.
-
Checking the availability and adequacy of the backup power supply to FDA panel and other electrically operated emergency equipments.
-
Type of cables used for emergency service.
Gas suppression system
-
Assess the requirement of Gas suppression system based on fire risk and criticality of the equipments / operations as per relevant standards.
-
Assessing the location of the Gas suppression cylinders, routing of pipeline, location of manual release and abort switches and panel, Standby power supply, etc
-
Checking the adequacy and deployment of the portable Fire extinguisher as per relevant standards.
-
Accessibility to extinguishers as per relevant standards and availability of refills, mounting practice, etc.
Passive fire protection
-
Segregation of the facilities and utilities, requirement of fire partition walls and its fire rating.
-
Segregation of power cables and data cables and utilities lines
Addressing the fire spread through vertical and horizontal openings meant for cable passes, utility lines, etc.
-
Fire rating of the emergency exit doors, Fire lifts, etc.
-
Fire rating of building construction, internal partitions and false ceilings.
Emergency Management & Life Safety System
-
Availability of Emergency preparedness plan.
-
Adequacy of emergency exit based on occupant load / type of occupancy / type of exit.
-
Adequacy and availability of emergency lights and ventilation.
-
Segregation of the emergency exit from the remaining facility.
-
Communication of emergency, Mutual Aid, etc.
-
Approach road width and clearance.
-
Access and egress to the building.
-
Open space around the building.
-
Adequacy of siganges.
-
Assess the requirement of passive fire protection system like cable pass sealants, etc.
-
Assessment of fire safety training level of security staff, and facility management staff.
-
Assessment of emergency plan, fire mockup drill records, evacuation plan and its adequacy